A purchase order for “M12 wedge anchors” leaves several questions open. How thick is the mounting plate? What concrete will receive the anchors? Does the project require documented performance in cracked concrete? Settling these points before ordering is usually easier than resolving a mismatch on site.
MetalVanta’s zinc-plated wedge anchor range covers six metric thread diameters and ten size combinations. It is a useful starting point for a size schedule, with the final selection checked against the project design and the technical documents for the exact anchor.
What the listed sizes mean
The available combinations are M8 × 75, M10 × 90, M12 × 100 and 120, M14 × 100, 120 and 140, M16 × 120 and 140, and M20 × 170 mm. Each designation gives the metric thread size followed by the nominal overall anchor length.
The current product specification lists carbon steel studs in property class 4.8, a zinc-plated finish, a hex flange nut and a separate flat washer. Confirm the supplied assembly against the quotation, especially when comparing offers that may use different hardware configurations.
Allow for the fixture before choosing the length
A thicker mounting plate uses more of the anchor’s available length above the concrete. Include the fixture thickness and the specified nut-and-washer arrangement when checking whether a length can accommodate the required embedment and fastening detail.
For example, M12 × 100 and M12 × 120 share a thread designation, but that alone does not establish which suits a particular base plate. Ask for the permitted fixture thickness and embedment arrangement for the selected product. Overall anchor length and effective embedment are separate dimensions. The difference between them cannot be treated as a universal allowance.
Check the concrete and the connection layout
Wedge anchors are installed in drilled holes in hardened concrete. Tightening the nut draws the tapered stud into the expansion clip, which expands against the hole wall. Typical enquiries involve equipment mounting plates, steel brackets, channel framing and pipe supports.
Before specifying a size, provide the concrete condition and thickness, the fixture drawing, the proposed anchor positions and the project loads. The responsible designer needs to check the connection using performance data that applies to the exact product and installation. A thread diameter or steel property class by itself does not provide an anchor load rating.
Where cracked concrete, seismic loading or another approval-dependent condition is involved, request documentation that explicitly covers the intended use. Keep the anchor spacing and distance to concrete edges visible on the drawing so they can be checked before the order is released.
Make the finish part of the enquiry
The listed range has a zinc-plated finish. Tell the supplier where the anchors will be installed, including exposure to moisture, outdoor weather or a corrosive atmosphere. Have the selected material and finish checked against the project’s corrosion requirements. A zinc-plated description alone does not establish suitability for every environment or a particular service life.
Request installation data for the selected size
Ask for the specified drill-hole diameter and depth, hole-cleaning method, embedment and installation torque. These values should come from verified instructions for the anchor being supplied. Keep those instructions with the installation team.
The basic sequence shown on the product page is to drill, clean, insert and tighten. Use the prescribed hole preparation, seat the anchor as instructed and apply the specified torque with a calibrated torque wrench. Resolve missing instructions before work starts rather than borrowing values from an anchor with a similar appearance.
Match ETA and CE documents to the order
If the project calls for ETA documentation or CE marking, request the applicable documents with the quotation. Check the product designation, manufacturer, included sizes, intended use and installation conditions against the proposed order. Ask the supplier to identify any requested sizes or conditions outside the documented scope.
An ETA assesses product performance for its stated scope. For procurement, the practical question is whether the documents supplied match the anchor and application being purchased. MetalVanta’s public product page does not identify an ETA number or provide the associated declaration, so document availability and scope should be confirmed for the enquiry before a compliance claim is accepted.
Send a size schedule that the supplier can quote
A workable enquiry includes each diameter and length, quantities, the fixture drawing, concrete information, exposure conditions, delivery requirements and the documents required for approval. Include any specified packaging or identification requirements if anchors will be distributed across several installation areas.
Review MetalVanta’s Zinc-Plated Wedge Anchors product page for the listed size combinations and assembly details. Send the proposed schedule and project requirements together so the quotation can identify the selected sizes, included hardware and technical documents available for review.
Discuss Your Requirement.
Tell us what your connection needs, with or without a drawing.
Start An Enquiry